Chloride
Test Code
CL
Description
Chloride - Serum chloride is the major extracellular anion and counter-balances the major cation, sodium, maintaining electrical neutrality of the body fluids. Two thirds of the total anion concentration in extracellular fluids is chloride and it is significantly involved in maintaining proper hydration and osmotic pressure. Movement of chloride ions across the red blood cell membrane is essential for the transport of biocarbonate ions in response to changing concentrations of carbon dioxide. Chloride measurements are used in the diagnosis and treatment of electrolyte and metabolic disorders such as cystic fibrosis and diabetic acidosis.
Collect
Plain red top or SST tube.
Pediatric Collection
Minimum volume: 0.15 mL serum
Unacceptable Conditions
Gross Hemolysis, Gross Lipemia
Storage Transport Temp
Offsite: Send frozen serum Priority Overnight via FedEx and in a well insulated container on dry ice.
Stability
Stability after cell separation:
8 hours at RT (15-25°C)
1 week refrigerated at 2-8°C
Performed
Monday - Friday
Methodology
Ion Selective Electrode
Turnaround Time
4 hour routine, 1 hour STAT
Department
Core Lab
Synonyms
Ion Selective Electrode (Chloride, Serum);CLX
Study Offerings
Not offered
Reference Interval
Chloride, Serum |
Human |
|
Male |
Female |
|
mmol/L |
||
Newborn - 29 Days |
99-116 |
99-116 |
1 Month - 11 months |
98-118 |
98-118 |
1 year - 4 years |
98-116 |
98-116 |
5 years - 9 years |
99-114 |
99-114 |
10 years - 15 years |
98-115 |
98-115 |
16+ years |
95-112 |
95-112 |
CPT Code
82435
New York Approved
FDA Approved or Cleared
FDA
Approved or Cleared